Codes of errors of groups of air conditioners, — AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu (Дайхатсу), Renova, – with the interchangeable printed-circuit boards with the same name. Drifting of pays of air conditioners of group on-default.

Derangement, representation of light-emitting diodes, — codes of errors of air conditioners. The timer light-emitting diode blinks what to do? What represent Light-emitting diodes? On these and other questions you find the answer …

Introduction in a code of representation of error AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Renova, Daihatsu and other air conditioners of series KFR, it HS, HSA, HSB, HSF, HV, with the terminations in names h3 HA HB, a series of air conditioners with the digital display of EU, EZ, EAA, EAD, EL, HS1, HSZ, HL1, HLZ, P, P1, ZZ, CZ, all other series Е, except for EA EU Е. M. Е Y. З EAA EAD, all series QA, QB, QD.

Derangement, representation of light-emitting diodes, — codes of errors of air conditioners. The timer light-emitting diode blinks what to do? What represent Light-emitting diodes? On these and other questions you find the answer …

1. HS (Y) HSA (Y), HSB (Y) HSF (Y) HV (Y) series business (Y)

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), Vitek, — the digital display for a series of air conditioners of derangement:

 Air conditioners of series KFR, it HS, HSA, HSB, HSF, HV, with the terminations in names h3 HA HB, a series of air conditioners with the digital display of EU, EZ, EAA, EAD, EL, HS1, HSZ, HL1, HLZ, P, P1, ZZ, CZ, all other series Е, except for EA EU Е. M. Е Y. З EAA EAD, all series QA, QB, QD.

Codes of errors of groups of air conditioners, – AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), Renova, – with the interchangeable printed-circuit boards with the same name.

Derangement of the power supply = PG a propeller return coupling abnormally
Representation regime = E4
Representation of level of a priority = 1

Неиmitsubishi52_63_71he-sсправность The power supply = Plastic the sensing transducer rate is abnormal.
Representation regime = E1
Representation of level of a priority = 2

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
Representation regime = E3
Representation of level of a priority = 3

Derangement of the power supply = the Copper temperature transmitter abnormal (break, there is no signal)
Representation regime = Е2
Representation of level of a priority = 4

2. Series Н, — AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), Renova (except for KFR-25G / H) h3 HA HB series of derangement the display:

Derangement of the power supply = PG a propeller return coupling abnormally
The representation regime = a timer Light-emitting diode blinks 4 times in everyone 8 ​​ seconds
Representation of level of a priority = 1

Derangement of the power supply = Plastic the sensing transducer rate abnormally
The representation regime = a timer Light-emitting diode blinks 1 time in everyone 8 ​​ seconds
Representation of level of a priority = 2

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
The representation regime = a timer Light-emitting diode blinks 2 times in everyone 8 ​​ seconds
Representation of level of a priority = 3

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
The representation regime = a timer Light-emitting diode blinks 1 time in each 1 seconds
Representation of level of a priority = 4

3. Series H (Y) model of the air conditioner the portable display, demountable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

Derangement of the power supply = PG a propeller return coupling abnormally
The representation regime = a timer Light-emitting diode blinks 4 times in everyone 8 ​​ seconds
Representation of level of a priority = 1

Derangement of the power supply = Plastic the sensing transducer rate. Abnormally
The representation regime = a timer Light-emitting diode blinks 1 time in everyone 8 ​​ seconds
Representation of level of a priority = 2

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
The representation regime = a timer Light-emitting diode blinks 2 times in everyone 8 ​​ seconds
Representation of level of a priority = 3

Derangement of the power supply = the Copper temperature transmitter abnormal (break, there is no signal)
The representation regime = a timer Light-emitting diode blinks 1 time in each 1 seconds
Representation of level of a priority = 4

4. Е. Е. Е. Ю. EU EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ the digital display of a series of air conditioners AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), troubleshooting :

Derangement of power supply AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = PG a propeller return coupling abnormally
Representation regime = E4
Representation of level of a priority = 1

 Е1 Or EL – as a frequent error on a food.

 Е1 Or EL - as a frequent error on a food of air conditioners of the given series.

Е1 Or EL – as a frequent error on a food of air conditioners of the given series.

Derangement of the power supply or on русски voltage in a network <210 In (protection – токовая loading operated) = the Sensing transducer rate abnormally
Representation regime = E1
Representation of level of a priority = 2

Е1 – Frequent enough error, literally yesterday faced.

    Reasons Е1 are obvious – insufficient voltage in a network <210 V.Pri compressor start-up occurs an additional slump of voltage, токовая loading max.

In my case Е1 – in an air conditioner operating mode on heat did not operate three running valve (did not open), there was no voltage on opening. As consequence – the compressor worked on itself → pressure raise → the current protection operated.

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
Representation regime = E3
Representation of level of a priority = 3

5. All other series Е, except for EA EU Е. M. Е. Ю. З EAA EAD:

Derangement of the power supply = PG a propeller return coupling abnormally
The representation regime = a timer Light-emitting diode blinks 4 times in everyone 8 ​​ seconds
Representation of level of a priority = 1

Derangement of the power supply = Plastic the sensing transducer rate. Abnormally
The representation regime = a timer Light-emitting diode blinks 1 time in everyone 8 ​​ seconds
Representation of level of a priority = 2

Derangement of the power supply = the Copper temperature transmitter abnormal (indoors)
The representation regime = a timer Light-emitting diode blinks 2 times in everyone 8 ​​ seconds
Representation of level of a priority = 3

6. QA QB QD the digital display of a series of air conditioners AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу),  Vitek, Renova – derangements, error codes:

Derangement of the power supply = PG a propeller return coupling abnormally
Representation regime = E4
Representation of level of a priority = 1

Group, wall air conditioners...

Derangement of the power supply = Plastic the sensing transducer rate abnormally
Representation regime = E1
Representation of level of a priority = 2

Derangement of the power supply = the Copper temperature transmitter abnormal
Representation regime = E3
Representation of level of a priority = 3

Derangement of the power supply = overloadings on a current oprotection
Representation regime = E6
Representation of level of a priority = 4

7. QC QQ the light display of a series of air conditioners of derangement:

Derangement of the power supply = PG a propeller return coupling abnormally
The representation regime = a timer Light-emitting diode blinks 4 times in everyone 8 ​​ seconds
Representation of level of a priority = 1

Derangement of the power supply = Plastic the sensing transducer rate abnormally
The representation regime = a timer Light-emitting diode blinks 1 time in everyone 8 ​​ seconds
Representation of level of a priority = 2

Derangement of power supply AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = the Copper temperature transmitter abnormal
The representation regime = a timer Light-emitting diode blinks 3 times in everyone 8 ​​ seconds
Representation of level of a priority = 3

Derangement of the power supply = overloadings on a current oprotection
The representation regime = a timer Light-emitting diode blinks 6 times in everyone 8 ​​ seconds
Representation of level of a priority = 4

8. Derangements of representation of a semiindustrial series 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), Renova – a wall series of air conditioners

Numbers for digital displays of a tube:

Derangement of the power supply = PG a propeller return coupling abnormally
The representation regime = a timer Light-emitting diode blinks 1 time in everyone 8 ​​ seconds
Representation of level of a priority = 2
System errors = switches out

Derangement of the power supply = Plastic the sensing transducer rate abnormally
The representation regime = a timer Light-emitting diode blinks 2 times in everyone 8 ​​ seconds
Representation of level of a priority = 3
System errors = switches out

Derangement of the power supply = the Copper temperature transmitter abnormal
The representation regime = a timer Light-emitting diode blinks 8 times in everyone 8 ​​ seconds
Representation of level of a priority = 4
System errors = it is not switched out

Digital tube of displays:

Derangement of the power supply = PG a propeller return coupling abnormally
Representation regime = E1
Representation of level of a priority = 2
System errors = switches out

Derangement of the power supply = Plastic the sensing transducer rate abnormally
Representation regime = E3
Representation of level of a priority = 3
System errors = switches out

Derangement of the power supply = the Copper temperature transmitter abnormal
Representation regime = Е2
Representation of level of a priority = 4
System errors = it is not switched out

The

circuit diagramme Group, wall air conditioners

The basic circuit diagramme of management of air conditioners: AUX, DAX, JAX, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, Daihatsu and their analogues.

The basic circuit diagramme of management of air conditioners: AUX, DAX, JAX, Pioneer, Hansa, Saturn, Vitek, Rolsen, Yamatsu, Daihatsu and their analogues.

The basic circuit diagramme of split-system 2500*1800

Models: repair of air conditioners of brands KFR-32GW/BP, KFR-45LW / D, KFR-3502GW/BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW/BP and other series KFR, PDF fail.  Тык.

Break much more often

Frequent breakages of air conditioners of a budgetary series are caused by that split-systems of lower price class break much more often as almost all knots, details, mechanisms of coolers are minimised at the price.

Air conditioners of series KFR, it HS, HSA, HSB, HSF, HV, with the terminations in names h3 HA HB, a series of air conditioners with the digital display of EU, EZ, EAA, EAD, EL, HS1, HSZ, HL1, HLZ, P, P1, ZZ, CZ, all other series Е, except for EA EU Е. M. Е Y. З EAA EAD, all series QA, QB, QD.

Codes of errors of groups of air conditioners, — AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu (Дайхатсу), Renova, — with the interchangeable printed-circuit boards with the same name.

Codes of errors of the whole groups of budgetary air conditioners, – AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Vitek, Daihatsu (Дайхатсу), Renova, – with the interchangeable printed-circuit boards with the same name. Drifting of a pay of devices охлаждния the given brands on-default.